Widely used for type 2 diabetes mellitus and obesity, glucagon-like peptide-1 receptor agonists (GLP-1RAs) may increase risk for injection-site reactions, especially exenatide and dulaglutide (Trulicity, Eli Lilly). However, generalized dermatologic events such as rash, urticaria, and hypersensitivity are rare with this class of drugs, according to new research.
For the study, researchers evaluated the dermatologic and injection-site reaction safety of GLP-1RAs via a meta-analysis of randomised controlled trials (RCTs) and a disproportionality analysis of data from the United States Food and Drug Administration Adverse Event Reporting System (FAERS). The pooled meta-analysis of 14 RCTs showed an increased risk of injection-site reactions with GLP-1RAs vs. comparators. Dermatologic events were infrequent and not significantly elevated. FAERS data analysis identified potential injection-site reaction signals for exenatide and dulaglutide. Exenatide was associated with injection-site hemorrhage, and dulaglutide showed disproportionate reporting for injection-site hemorrhage, the researchers report.
“These insights can help guide safer prescribing decisions and enhance patient monitoring in routine clinical practice,” the study authors conclude.